Detectomat on design conscious fire detection
David Leigh of Detectomat UK reviews potential for design conscious fire detection solutions using new product and system developments from the fire industry.
Blending with traditional interiors and keeping up with changes in interior design styles and moods is a challenging task for suppliers of building components.
Design cover options from detectomat
However, a review of the general range of smoke detectors available suggests that this challenge has until recently been totally missed or not taken up by most Fire Detection and Alarm companies.
The need for aesthetically pleasing devices is applicable to New Build and Refurbishment or Retrofit applications.
In the latter two areas there is also the issue of installation time, access, damage to decoration, ugly surface wiring and general disruption, which can lead to "unhappy clients".
These are the current issues.
Facility Managers, builders and developers need a solution to the complex requirements of providing good fire protection whilst at the same time ensuring rapid, cost-effective installation with minimal business disruption.
Fire Detection needs to be attractive, complement the decor and avoid the need for ugly surface wiring or damage to decorations from installing concealed wiring.
Standards and the legislative framework Solutions to the above issues are emerging but, before we review them, we should review the Standards and Legislative environment in respect of Fire Detection and Alarms.
For New Build or Major Refurbishment - Building Regulations Part B covers all the fire detection and protection requirements in any type of dwelling in the UK, with the exception of prisons.
Section 1 covers dwellings - including large houses, loft conversions and sheltered housing plus commercial and industrial properties.
Section 2 covers HMOs, which are single family residences converted into a number of small flats or bed sitting rooms so that the status changes from a family residence to a multi-person residence.
In respect of Residential New Build, the minimum requirement, as per Building Regulations, is 240vAC interlinked self-contained alarms or a suitable BS5839 part 1 or part 6 solution.
However, it should be noted that BS5839 is a Code of Practice, which has scope for implementation with variations subject to individual site by site Risk Assessments and agreement by the Designer, Installer and end client.
Part 1 is a code of practice, which mainly applies to the installation of fire detection systems for commercial and industrial applications.
It is considered to be the Bible for the fire industry, including the fire services.
Part 6 is a code of practice, which covers a wide range of residential properties from bedsits to castles! The Fire Services Regulatory Reform (Fire Safety Order) or RRO, which came into effect in October 2006 represented a major Fire legislation change, building on and replacing the 1999 Fire Precautions in the Workplace act, which started the move from prescriptive to risk based assessment.
This order, to be policed by Fire Services, is a risk based assessment emphasising fire prevention implemented by responsible and competent persons.
Fire Sytem components and Design Conscious Solutions A Fire Detection and Alarm system should be appropriate to the task as determined by risk assessment, conform with, relevant BSEN Standards and comply with the Building Regs.
There can be many alternative solutions to achieving the cover or level of protection required.
However, some are more Design Conscious than others.
For example, most detection and alarm systems require automatic detection and there is a large range of suppliers but most smoke detectors have been designed by electronic engineers with little or no regard for aesthetics.
However, products are now emerging, which recognise that aesthetic design is as important as detection performance.
And the Designer Range below is such an example, providing self-contained alarms, conventional and addressable detectors with a range of Designer covers and colours -white, black, satin silver or glass to match traditional or contemporary interior designs, see inset- Integrated Detector/Sounder/Beacon products and the opportunity to semi-recess detectors as per the earlier picture at the beginning of this article are other areas in field devices, where consideration of aesthetics is coming through in modern designs.
Control and Indication panels are also an area, where size and design are an important factor and here too we've seen significant reductions in size over the years with considerably more thought being given to aesthetics as the example inset- Wire-free Radio as part of a Design Conscious Solution All Fire Systems require an interconnection of the various components including detectors, manual call points, sounders and control panels, which is normally done in electrical cabling or commonly termed hardwiring.
Installing cables in existing buildings is time consuming and presents access issues, damage to decoration, ugly surface wiring and general disruption, which can lead to "unhappy clients".
All of these issues can be resolved or avoided with Wire-free or Radio Fire Alarms providing a far more design conscious solution and "happier clients".
Radio, as a communication medium has been available for many years at a high cost.
However, application of the latest technology has produced wire-free systems, which can provide cost-effective solutions for systems as small as two self-contained alarms in a residence or as large as a shopping centre.
Systems currently available range from networked wire-free, Analogue Addressable systems to radio alternatives to single Addressable loop or Conventional panels as inset- Hybrid or Gateway systems have also emerged.
This is where a hardwired Analogue Addressable system can be extended or initially configured with one or more Radio Gateway.
If a Facility Manager is faced with the need to extend fire detection coverage to comply with an updated Fire Risk Assessment this can provide a useful and cost-effective solution.
Facility Managers and Owner/Managers want the highest level of safety for their building occupants but they also want to avoid disruption and damage to the building decoration and fabric, which only a wire-free solution can provide.
The need to avoid disruption and damage is wide reaching and as a consequence the demand for wire-free solutions is significant as a proportion of the overall market and growing at a rapid rate and Listed buildings are of course one of the most sensitive areas In conclusion, Design Conscious Fire Detection is now available through a combination of Designer detector covers to complement contemporary or traditional designs, modern panel designs and wire-free radio systems to reduce installation time, damage to decoration, ugly surface wiring and general business disruption.
Not what you're looking for? Search the site.
Tel +44 1579 321750
-
Detectomat fire alarm system fitted at guest house
A Detectomat system has been specified to provide fire protection at a restored Victorian property. -
Detectomat offers fire safety for temporary sites
Stockport Fire Protection has selected the Detectomat SRC 3000 wire free radio fire alarm system for the fitting out of temporary accommodation. -
Fire protection from Detectomat for listed church
Detectomat has provided wireless fire protection at a 12th century listed church which has recently undergone a refurbishment programme. -
Banwell castle gets Detectomat fire protection
The Detectomat SRC 3000 fire protection system has been selected for use at the historic Banwell Castle in Somerset. -
Detectomat system used in historic buildings
The Detectomat Wireless detect system is being used for historic buildings in Cheltenham after being recommended by Mainpoint Fire Protection.
Browse by category
- Building Industry News (7919)
- Information Technology (2961)
- Building Structures and Products (15785)
- Building Services (11320)
- Building Systems (1482)
- Security and Fire Protection (2472)
- Site Preparation (1588)
- Landscaping (563)
- Plant, Equipment and Hire (1776)
- Civil Engineering (1465)
- Interiors (1258)
- Latest Exhibitions and Awards (24)