Radio capability extends fire systems
System Sensor's new radio communications between detectors, call points and panel will reduce the implementation cost of the fire system.
In heritage sites, installing fire detection system cables can sometimes be a particularly expensive and difficult process as the historic architecture of the building has to be respected Similarly, in buildings with particularly thick floors and walls or an unusual layout, installation costs can again be significantly increased
This article was originally published on Buildingtalk on 29 Jan 2008 at 8.00am (UK)
Related stories
COPTIR stable fire detector cuts false alarms
System Sensor, the world's largest detector manufacturer, is approaching the issue through technology development by stopping false alarm generation in the first place.
Eco friendly alternative to ionisation detectors
System Sensor Europe extends its product portfolio of high performance addressable fire detectors with the introduction of PTIR; the Photo Thermal Infra-Red detector.
In such situations, radio communications between the detectors, call points and panel will reduce the implementation cost of the fire system.
System Sensor's new radio capability consists of a stand alone radio based system and extension to the traditional Series 200 plus wired system.
The addressable system consists of a gateway module that extends the wired system on the loop, by translating the radio detectors address into a wired equivalent.
Up to 98 radio call points and 99 radio detectors can be addressed through each module, each detector being seen as a unique address by the panel.
The unit's range is 300m in free air, automatic frequency and channel changing through channel monitoring guarantees robust communications between the module and devices.
The stand-alone control panel controls up to 32 detectors or call points in two fire zones.
Both the addressable and conventional units sequentially interrogate each radio detector and radio call point every 90 seconds.
The radio detector is approved to EN54 part 7.
It consists of a fixed sensitivity optical chamber, and two 57degC fixed temperature detectors; all three detectors operate independently of each other, the device signals an alarm condition when any one detector goes into alarm.
Two types of call point are available: a dual-action German style call point or European style KAC call point.