Safeguard research shows homes at risk despite damp treatment

  • 16 Jan 2019

Research from Safeguard Europe has suggested that homes nationwide could be at risk from rising damp, despite being equipped with chemical damp-proof courses (DPCs).

The UK’s leading specialist in damp-proofing and waterproofing technology has conducted tests at its research and development laboratory, which have proven that DPC creams with low concentrations of silicone will ultimately prove ineffective.

DPC creams work because they contain silicone that penetrates the pores of the mortar in masonry and brickwork to form a waterproof seal.

Some DPC creams on the market contain as little as 10% silicone, but UK testing and certification takes no account of the silicone content of these creams and their consequent performance.

Only comparative testing on a range of products will demonstrate these differences, so Safeguard pitted its own high-silicone content products, Dryzone Damp-Proofing Cream and Dryzone Damp-Proofing Rods, against two DPC creams that contained 20% and less than 15% silicone respectively. All four products are certified by a leading UK test house.

The experiment consisted of preparing five pieces of lime mortar, each with a hole in the centre, which were left for four weeks.

Safeguard Europe

Then, each was injected with one of the DPC treatments, with one piece left untreated as a control for comparison.

They were left to cure for a further four weeks and then split in two to reveal the extent of the waterproof zone.

SE1901TB Safeguard Europe DPC Strength Time Bomb #2

The results were in line with earlier research by the University of Portsmouth, showing the size of the waterproof zone around the injection holes is relative to the amount and strength of active material injected.

The low strength creams do not create a waterproof zone as large as that produced by high-strength products such as Dryzone Damp-Proofing Cream or Dryrod Damp-Proofing Rods, which diffuses silicone throughout the pores of the mortar when inserted into drill holes.

This means that the low strength creams are more likely to fail because the further the spread the more effective the treatment. If the creams do not spread far enough then, they will still allow moisture to rise in those areas they do not reach.

Contact:

Safeguard Europe,
Redkiln Close,
Horsham,
West Sussex,
United Kingdom,
RH13 5QL

Phone: 01403 210204
Fax: 01403 217529

Visit Safeguard Europe's website

Leave a Reply

More articles

Cembrit launches new fibre cement cladding

Cembrit has announced the launch of a new through-coloured cladding board with a sandblasted surface, Patina Rough.

Posted in Articles, Building Industry News, Building Products & Structures, Cladding, Innovations & New Products, Posts, Walls

Ahmarra exceeds expectations in Ministry of Housing fire door test

Sample timber fire doors from Ahmarra Door Solutions recently exceeded expectations when tested against regulations.

Posted in Articles, Building Industry News, Building Products & Structures, Doors, Health & Safety, Research & Materials Testing, Security and Fire Protection

EverEdge chosen for Islington Square project

EverEdge was recently specified to provide edging and planters for a project for Cain International at Islington Square in London.

Posted in Articles, Building Industry News, Building Products & Structures, Garden, Posts

How do you maintain LST radiators?

Contour discusses maintaining LST radiators and ensuring that they are consistently meeting their expected potential.

Posted in Articles, Building Industry News, Building Products & Structures, Building Services, Heating Systems, Controls and Management, Posts