512/522 Streatham High Road is a new mixed-use development of storage and office space, which features a plethora of products from Delta Membranes.

Delta’s Director, David J. Symes, was delighted to have been involved with this prestigious project from concept, which involved a basement with a footprint of an impressive 1500 square metres (wall surface) and 2500 square metres (floor surface).

Harmonix were appointed main contractor to create a five-storey structure, which included a two-storey basement. Initially, the area was excavated to approximately 13,700m cubic metres, using contiguous piling to form two basement levels.

A new structural concrete slab was laid with three lift pits, with the piles having then been faced with a concrete lining wall. 

The project required a robust and a meticulously detailed specification with Delta Registered Installers, Cemplas being appointed waterproofing contractor to guarantee a watertight basement.

The project requirement was for two forms of waterproofing which consisted of a Type B watertight concrete and Type C Cavity Drainage Membrane System which would meet all criteria of BS8102:2009 (Code of Practice for Protection of Below Ground Structures against Water from the Ground) and to provide a Grade 3 habitable environment.

Delta Membranes

Methodology

When designing a robust waterproofing solution, attention to detail is critical.  The waterproofing design for any new build below ground structure should always be carried out by a CSSW (Certified Surveyor in Structural Waterproofing) or equally qualified surveyor. 

When specifying a Type C cavity drainage membrane system, full consideration must be given to the drainage aspect, when installed below ground.  

Before the installation of the Type C System, the lift pits and piling cap were encapsulated with Koster NB1 waterproof slurry. Koster NB1 active migratory crystalline slurry was applied over the capping beam and taken across the underside of the ground floor soffit to provide protection against the expectation of lateral capillary movement and down the front face of the concrete lining wall.

To reduce the risk of free lime leaching out of new concrete during the curing process, Koster Polysil TG 500 was applied to the face of the concrete lining wall.

After ensuring the structure was watertight, Delta MS 500 Cavity drain membrane was installed to the walls and applied to the face of the concrete lining wall.

Delta Membranes

Cavity Drainage Systems manage water penetration, Delta drainage channel, a water collection conduit designed to control water ingress was bedded into a preformed recess/gully at the floor/wall junction with incorporated inspection and maintenance points to comply with BS8102:2009.

Prior to the application of approx. 2500 square metres of Delta MS20 membrane the basement slab was thoroughly flood tested which extended to the vertical cavity drain membrane and results recorded on the Delta/Cemplas site monitoring forms to ensure the free passage of water had unhindered access to the sumps.

This is an important part of the testing where installing Type C systems and ensures that any debris behind the system is fully flushed away preventing issues in the future and designing out risk.

Locations of the sump pump units were suggested during the design phase. By incorporating sump pumps at the design stage, it allowed for project team to work together to create and share a range of project documentation with the benefit of interconnectivity which in turn created better project decisions during the correct stages of the project.  

Delta Membranes

Products

 – Delta MS 20
 – Delta MS 500
 – Koster Polysil TG 500
 – Koster NB1

Case Study Results

The project successful reflects the relationship between Delta and Cemplas.  Highly accomplished project performance from concept with complete customer satisfaction. 

Cemplas have created a completely dry and habitable Grade 3 environment two-storey basement which fully complies with all criteria set in BS 8102:2009. 

Delta described it as ‘a pleasure’ to work with Cemplas and that it looks forward to the next project.

Delta Membrane Systems,
Delta House,
Merlin Way,
North Weald,
Epping,
Essex,
CM16 6HR
United Kingdom

Visit Delta Membrane Systems' website

Leave a Reply

Latest news

Senior

Senior just the ticket for new rail station development

Senior Architectural Systems, the UK’s largest privately owned aluminium fenestration systems house, has played a key role in the transformation of Coventry’s rail station to create a welcoming entrance to the city.

Posted in Aluminium Products, Articles, Building Industry News, Building Products & Structures, Building Systems, Canopies, Entrances & Column Casings, Case Studies, Cladding, Curtain Walling, Doors, Facades, Glass, Glazing, Restoration & Refurbishment, Retrofit & Renovation, Walls, Windows

Newton

Newton Waterproofing: 21 basements in one project

The £6.7 million Rectory Gardens development is in the prestigious Clapham Old Town area of South London – it features a range of products from Newton Waterproofing.

Posted in Articles, Building Industry News, Building Products & Structures, Building Services, Case Studies, Damp & Waterproofing, Facility Management & Building Services, Membranes, Posts, Restoration & Refurbishment, Retrofit & Renovation

IG Masonry Support

IG Masonry Support: Sommerville College, Oxford

For new high quality, contemporary student accommodation at Somerville College in Oxford, IG Masonry Support was able to create a solution.

Posted in Articles, Bricks & Blocks, Building Industry News, Building Products & Structures, Case Studies, Drainage, Guttering, Soffits & Fascias, Facades, Restoration & Refurbishment, Retrofit & Renovation, Walls

VORTICE's HR200 BP installed in 45 properties near Sleaford

VORTICE has supplied heat recovery units for 45 new affordable homes in the Heckington and Sleaford area. The design specification for the homes meant the unit needed to be installed under the stairs. Therefore, due to its compact dimensions, the Vort HR200 BP unit was an ideal choice.

Posted in Air Conditioning, Articles, Building Industry News, Building Products & Structures, Building Services, Case Studies, Facility Management & Building Services, Heating Systems, Controls and Management, Heating, Ventilation and Air Conditioning - HVAC, Restoration & Refurbishment, Retrofit & Renovation, Sustainability & Energy Efficiency