Fire doors – top ten tips

  • 27 Nov 2013

Fire safety in public buildings is of paramount importance due to their high usage, but also because of our unfamiliarality with these buildings’ fire escape routes and procedures.

For all involved in designing, constructing and running these buildings, fire safety routes and devices need to be well thought out to meet the requirements of the building and its users.

One fire safety device that plays a key role is fire doors. Fire doors work as part of a building’s passive fire protection system by containing fire and smoke through compartmentation. This allows the fire to be kept to one area, preventing fire and smoke from spreading, while occupants use an alternative route to escape.

The specification and installation of the fire door is highly significant. It must meet the requirements of the building and be made of high quality materials incorporating all necessary components to ensure it will work as an engineered safety device. Third-party certificated timber fire doors are the essential choice as they have undergone rigorous testing and auditing to prove their effectiveness.

Third-party certification consists of more than a certificate. It shows that the fire door’s design, performance, manufacturing process and quality assurance have been tested and verified from manufacture to installation. This puts the architect and building owners’ minds at rest and provides confidence that the product will perform when installed correctly.

It is important however, to make sure the specification of the door truly meets the requirements of the building. Considerations such as how often the doors will be used and where they will be placed can have implications on which fire door to choose. In the case of the BWF-CERTIFIRE Fire Door Scheme, fire doors are fitted with a label detailing the manufacturer of the door, the certification number, a unique serial number and the door’s fire rating. This not only confirms that the installer has used the product that was originally specified, but also allows the building owner to trace the product should they need to source the manufacturer, the certificate and even the history of the door, if it has been separately processed, such as with the addition of glazing apertures. To add to the installation requirements, the door frame should be third-party certificated and the ironmongery must be certificated and CE marked.

When a fire door has been chosen, the next step is to ensure it is fitted by a competent installer. Fire doors are not ordinary doors, as mentioned previously, they are an engineered safety device and require care and close attention when being installed.

Once the fire door is installed, the need for any inspection and maintenance falls upon the Responsible Person as named under the Regulatory Reform (Fire Safety) Order, or RRO or the Duty Holder under the Fire Scotland Act : 2005 – usually the building owner, manager, or facilities manager. It is their responsibility to manage fire risk within the building and put into place the necessary procedures.

This can be a daunting task so here is a ten point checklist on how to meet fire door safety in public buildings:

1. Check the label. Third-party certificated fire doors have been independently tested and verified, all information will be found on the label and will prove that the door has an official fire rating.

2. Check the door leaf. The door leaf should not be damaged, warped or twisted. Any of these defects will affect the fire door from functioning correctly. But don’t patch up any damage, you must replace the door.

3. Check that the door shuts. The door should fit into the frame when closed and the frame should be firmly attached to the wall.

4. Check the seals. Ensure the seals at the top and sides of the door are present and are not damaged.

5. Check the gap. The gap around the door should be consistent at 3mm plus or minus a millimetre.

6. Check the closer. Open the door from about 75mm from the closed position and let go to make sure the door will shut. The door should engage with the latch where one is required.

7. Check the hinges. All hinges should be firmly fixed to the door and frame and there should be
no screws missing.

8. Check the glass. If there is any glass on the door, check it for cracks and make sure the beads holding the glass are fitted firmly. There should be a continuous intumescent seal attached
to the glass and bead.

9. Check the signage. All fire doors require appropriate signage to ensure building occupants are aware of its purpose.

10. Check it is not open. Ironically, fire doors are often propped open with fire extinguishers. It is essential that fire doors are kept shut unless they are fitted with automatic closers in the event of a fire.

Ideally, fire doors should be checked at least every three months for high usage buildings – moreso in very high traffic areas – and every six months for low usage buildings. Performing these checks is imperative for the Responsible Person to ensure fire safety standards are consistently met. If there is any doubt over a particular door, he or she should seek expert advice from a competent person. Fire doors are a life saving device and will only function correctly if they are well looked after.

Leave a Reply

Latest news

Renderplas

Renderplas shadow gap beads throw shade

For architects and designers looking to avoid traditional skirting boards, architraves and cornices, Renderplas offers its range of PVC plasterboard shadow gap beads for dry lining systems.

Posted in Articles, Building Industry News, Building Products & Structures, Floors, Interior Design & Construction, Interiors, Posts, Render, Restoration & Refurbishment, Retrofit & Renovation, Walls

MCRMA

First MCRMA members’ roadshow takes place at Siderise

Members of the MCRMA, the trade association for the metal cladding and roofing industry, had an exclusive opportunity to explore and discuss the changes affecting the construction sector at the first of the association’s roadshow events hosted by Siderise at its HQ and manufacturing facility in South Wales.

Posted in Articles, Building Associations & Institutes, Building Industry Events, Building Industry News, Building Products & Structures, Building Regulations & Accreditations, Building Services, Cladding, Exhibitions and Conferences, Health & Safety, Restoration & Refurbishment, Retrofit & Renovation, Seminars, Walls

BMBI
Hambleside Danelaw

Hambleside Danelaw: Innovation to Installation - MidVerg20®

Hambleside Danelaw’s MidVerg20® interlocking verge system was manufactured to suit all flat intermediate gauge single-lap interlocking tile types, and can be installed on both new builds and refurbishments.

Posted in Articles, Building Industry News, Building Products & Structures, Building Services, Innovations & New Products, Posts, Restoration & Refurbishment, Retrofit & Renovation, Roofs