For any below ground structure, basement drainage should always be considered essential, Delta Membranes explain here…
Even with site investigations at the planning stage, this is only a snap shot in time. Groundwater is expected to come to bear against the structure at some point during its service life.
BS8102:2009 states “…waterproofing measures should be designed on the basis of water to the full height of the retained ground at some time during the structure’s life…”
Groundwater is the most commonly forgotten aspect of the Water Cycle, as it is not readily seen. The Water Cycle is the constant movement of water through the environment, travelling as slowly as a metre per year.
Evaporation of ocean water condenses into clouds ready for rainfall across the land. After rainfall, the surface rainwater flows back into rivers and the sea.
Water pressures acting on the external retaining wall system and water pressures below the basement slab should always be key factors for reducing risk when designing a robust waterproofing solution.
The design should enable the system specified to withstand a pre-determined head of water or control any water ingress before it reaches the structure.
Type C waterproofing systems do not provide a hydrostatic barrier against water ingress but provides a controlled means of water management.
There are two main systems, both work alongside a Type C Cavity Drainage System to collect and manage water these are Perimeter Drainage and Modular Drainage.
Without fail, the most popular specified system is Perimeter Drainage. All drainage systems for a Type C cavity drain system should be designed specifically for each site/project – perimeter channel, modular or a combination of both, all need to be maintainable.
Drainage channels are water collection conduits designed to manage and control water ingress. These channels are installed around the perimeter of a basement, cellar or below ground structure.
They feature a number of preformed holes that allow any water from the Type C cavity drainage system to enter the channel, then drain into a sump pump (submersible pump station) or suitable discharge point.
Once collected in the sump chamber, the groundwater can then be pumped to a safe designated point of discharge off site.
Drainage channels are available with or without upstands, and are supplied in durable straight lengths, the use of T-junctions, corner pieces, straight connectors, jetting eyes, end caps and access ports.
An alternative to perimeter drainage is a modular drainage system. Using a 110mm standard underground drainage pipe, this system is only suitable for new construction or when a new concrete slab/raft is being replaced with a reinforced slab/raft.
Drainage should be installed at uniform gradients, not less than 1:100. Piped drainage systems should be tested for leakage prior to backfilling and concreting.
When specifying and designing modular drainage systems, we would suggest liaising with Delta’s Technical Team.
When designing any basement drainage system, philosophy and approaches should always be based on functionality, quality and maintainability. All drainage systems, must be maintainable!
Delta Membrane Systems,
Delta House,
Merlin Way,
North Weald,
Epping,
Essex,
CM16 6HR
United Kingdom
Visit Delta Membrane Systems' website
Sustainable block manufacturer, Lignacite, has taken the initiative to fast-track its journey to net zero by switching its on-site plant vehicles to HVO fuel.
Posted in Articles, Bricks & Blocks, Building Industry News, Building Products & Structures, Building Services, Facility Management & Building Services, Plant, Equipment and Hire, Retrofit & Renovation, Site Preparation, Sustainability & Energy Efficiency, Waste Management & RecyclingThe latest figures from the Builders Merchant Building Index (BMBI), published in March, reveal that builders’ merchants’ value sales were up +0.2% in January 2023 compared to the same month in 2022.
Posted in Architectural Ironmongery, Articles, Bathrooms, Bedrooms & Washrooms, Bricks & Blocks, Building Associations & Institutes, Building Industry News, Building Products & Structures, Building Services, Building Systems, Doors, Drainage, Health & Safety, Heating Systems, Controls and Management, Heating, Ventilation and Air Conditioning - HVAC, Interior Design & Construction, Interiors, Kitchens, news, Paints, Plumbing, Posts, Research & Materials Testing, Sustainability & Energy Efficiency, Timber Buildings and Timber ProductsThe scope of a recent Delta project was to specify and install a remediation basement drainage system to a property in London.
Posted in Articles, Building Industry News, Building Products & Structures, Building Services, Case Studies, Damp & Waterproofing, Drainage Services, Drainage, Guttering, Soffits & Fascias, Facility Management & Building Services, Membranes, Restoration & Refurbishment, Retrofit & Renovation, WallsGeberit has launched a new multi-layer supply piping system to the UK market after eight years of intensive research and development.
Posted in Articles, Bathrooms & Toilets, Bathrooms, Bedrooms & Washrooms, Building Industry News, Building Products & Structures, Building Services, Innovations & New Products, Interiors, Pipes & Fittings, Plumbing, Posts, Research & Materials Testing, Retrofit & Renovation