Delta solves damp problem at Bath nightclub

  • 30 Sep 2019

Delta Membrane Systems products were recently chosen to help prevent damp related problems in vaults in Bath.

Bath’s vaults are said to be an integral part of the area’s historic integrity in both architectural and social historic terms. Although vaults in Bath are subterranean spaces, they were built on what was the original ground level.

Therefore, many of the vaults within historic Bath suffer with water ingress and damp related problems. Delta Registered Installers, Cannon Clarke were commissioned to design and install a guaranteed waterproofing solution for Po Na Na, a Moroccan-themed nightclub venue situated in a vaulted cellar in Bath’s popular Parade area. The vault was suffering high volumes of water ingress during rainfall due to the road above.

During initial onsite inspections, it was evident that the original tanking system used within this venue was failing. It’s believed the vault had originally been tanked over 50 years ago. In keeping with the Local Planning Authority’s position in determining listed building applications for their alteration and for damp proofing works, it was agreed that the venue owners could update the tanking system.

Cannon Clarke designed and installed a Type C Drained Protection waterproofing system incorporating Delta’s BBA Certified MS 20 and MS 500 membranes. The walls were treated using Delta MS 500 Cavity Drain Membrane.

The Delta MS20 and MS 500 Membrane Systems have been specified in many Grade 1 and 2 listed buildings throughout the United Kingdom due to its sympathetic value. The Delta Membrane System offers an ‘air gap’ technology which is favoured by English Heritage, The Society for Protection of Ancient Buildings (SPAB) and local authority conservation officers.

The Delta Membrane System itself doesn’t need any aggressive preparation, therefore, it will not create damage to historical or heritage structures. The Delta Membrane System is a reversible system, which can easily be removed at any time, retaining the structure underneath intact.

The project saw the wooden nightclub floor replaced with a concrete floor which has allowed for a fully serviceable perimeter drainage channel to be installed, discharging to a combination of passive and powered disposal points. An application of Koster Polysil TG 500 (an anti-lime coating/surface primer) was installed to reduce the risk of excess free lime leaching out of the concrete during the curing process. This free lime, if untreated, can enter the Cavity Drainage System which can impede the flow of water and cause sump pump failure. To seal the floors prior to finishes being applied Delta’s MS 20 flooring Cavity Drainage Membrane was installed.

Overall, Cannon Clarke was able to design and install an ideal remedy for this listed building as the Delta MS 20 and MS 500 system is deemed ‘reversible’ satisfying local planning authority recommendations. In addition, the Delta System complies with BS 8102:2009 ‘Code of practice for protection of below ground structures against water from the ground’ and has an EN1350-1 Class E fire reaction classification.

Delta Membrane Systems,
Delta House,
Merlin Way,
North Weald,
Epping,
Essex,
CM16 6HR
United Kingdom

Visit Delta Membrane Systems' website

Leave a Reply

Latest news

CUPA PIZARRAS

Snowdonia approves CUPA PIZARRAS ‘CUPA 12’ Slate

Snowdonia National Park Authority, the local planning authority for Wales’ largest national park, has approved a second CUPA PIZARRAS slate for use on roofs in the prestigious area.

Posted in Articles, Building Industry News, Building Products & Structures, Case Studies, Restoration & Refurbishment, Retrofit & Renovation, Roofs

C-TEC

C-TEC’s CAST fire system specified for Stiller’s new site

C-TEC’s innovative CAST XFP addressable fire alarm system has been specified for a high-tech logistics site in County Durham.

Posted in Articles, Building Industry News, Building Services, Case Studies, Health & Safety, Innovations & New Products, Retrofit & Renovation, Security and Fire Protection

Selectaglaze

Towering Gothic Arches at Harris Manchester College fitted with Selectaglaze secondary glazing

Harris Manchester College’s late Victorian buildings contain large stained-glass windows that now feature Selectaglaze secondary glazing.

Posted in Articles, Building Industry News, Building Products & Structures, Case Studies, Glass, Glazing, Posts, Restoration & Refurbishment, Retrofit & Renovation, Windows

Abloy UK

Getting smart with security - Abloy UK

This piece sees Pip Courcoux, Sales and Product Manager at Abloy UK, look at the integrated functionality and flexibility security systems require to make buildings smarter. 

Posted in Articles, Building Industry News, Health & Safety, Information Technology, Innovations & New Products