GGF issues statement on CPR and insulating glass units

  • 22 Jul 2019

The Glass and Glazing Federation (GGF) has issued a statement responding to the sixth year of Construction Products Regulations (CPR) being the legal requirement in the UK.

The CPR (which replaced the Construction Products Directive) was implemented in the UK, on 1st July 2013 and requires all construction products placed on the market, which fall within the scope of a harmonised European Standard (hEN), to have a Declaration of Performance (DoP) produced by the manufacturer and be CE Marked in accordance with the requirements of the CPR.

In terms of Insulating Glass Units (IGUs), the relevant hEN (Harmonised European Norm) is EN 1279-5:2018 – Product Standard, this standard details the requirements to comply with the CPR. In turn, EN 1279-5:2018 requires IGU manufacturers to have test evidence to show compliance with:

  • EN 1279-2:2018 – Long term test method and requirements for moisture penetration
  • EN 1279 3:2018 – Long term test method and requirements for gas leakage rate and for gas concentration tolerances
  • EN 1279-4:2018 – Methods of test for the physical attributes of edge seal components and inserts; and a system description in accordance with EN 1279-1:2018 – Generalities, system description, rules for substitution, tolerances and visual quality.

IGU manufacturers must also operate a Factory Production Control in compliance with EN 1279-6:2018 – Factory production control and periodic tests.

The CPR does allow manufacturers to refrain from drawing up a DoP and CE Marking products under certain circumstances, these are known as derogations and are detailed in Article 5 of the CPR. There are three conditions under which a derogation is allowed. These are detailed in the GGF publication, ‘Insulating Glass Units (IGUs) – Conforming to the Construction Products Regulation (CPR)’, which can be downloaded from the Members Area on the GGF website. 


This publication also details the GGFs interpretation on the application of these derogations in relation to IGUs being placed on the market. The GGFs position is that the derogations do not apply to the manufacture of any IGUs and Best Practice advice to Members, is to ensure they always have their products tested to the appropriate parts of EN 1279 series, have a system description specific to all specifications of IGUs they manufacture, have an appropriate Factory Production Control in accordance with EN 1279-6:2018 and create a DoP and CE Mark for their product ranges. This is also clarified in CPR document 07/07/1 from the European Commission.

By following the GGFs guidance, IGU manufacturers will be able to demonstrate compliance with the product standard, EN 1279-5:2018 and comply with the legal requirements of the Construction Products Regulations.

Contact:

Glass and Glazing Federation
40 Rushworth Street
London
SE1 0RB
LONDON

t: 0207 939 9101

Visit the Glass and Glazing Federation (GGF) website

Leave a Reply

More articles

Granada Glazing

Granada’s secondary glazing ensures sound night’s sleep for London hotel guests

Guests at a central London hotel located seconds away from Fleet Street can enjoy a peaceful and comfortable night’s sleep thanks to Granada Glazing.

Posted in Aluminium Products, Articles, Building Industry News, Building Products & Structures, Building Systems, Case Studies, Glass, Glazing, Posts, Restoration & Refurbishment, Retrofit & Renovation, Windows

Wrightstyle

Steel glazing specialist Wrightstyle goes underground

Wrightstyle, the steel glazing systems company, has been appointed to design, supply and install fire rated screens to the new Tube station at Battersea Power Station.

Posted in Articles, Building Industry News, Building Products & Structures, Building Systems, Case Studies, Curtain Walling, Glazing, Posts, Restoration & Refurbishment, Retrofit & Renovation, Steel and Structural Frames, Walls, Windows

Closomat

Housing with care; thinking outside the box with Closomat

The use of assistive technology in housing is receiving additional relevance with the publication of new research and strategies, as Closomat explain here…

Posted in Accessibility, Articles, Bathrooms, Bedrooms & Washrooms, Building Industry News, Health & Safety, Interiors, Posts, Research & Materials Testing

Newton Waterproofing

Another Star Newtonite Gains CSSW Qualification

Vince Tansey, Business Development Manager and recent addition to the Newton Waterproofing family, has recently gained the highly desirable CSSW qualification.

Posted in Articles, Awards, Building Industry Events, Building Industry News, Building Products & Structures, Building Regulations & Accreditations, Building Services, Damp & Waterproofing, Posts